#grayscale");filter:gray;-webkit-filter:grayscale(100%);}.bk-root .bk-logo-small{width:20px;height:20px;background-image:url(data:image/png;base64,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);}.bk-root .bk-logo-notebook{display:inline-block;vertical-align:middle;margin-right:5px;}.rendered_html .bk-root .bk-tooltip table,.rendered_html .bk-root .bk-tooltip tr,.rendered_html .bk-root .bk-tooltip th,.rendered_html .bk-root .bk-tooltip td{border:none;padding:1px;}
This is a collection of measured CCS, RT, and theoretical m/z for 19 commonly used quaternary ammonium compounds (QACs) and their phase I hepatic metabolites. Chromatographic separation was performed with a Waters Acquity UPLC, which was equipped with a quaternary solvent pump coupled to a reversed-phase Phenomenex Kinetex C8 column (100 x 2.1 mm, 1.7 uM particle size).
Chromatographic gradients consisted of varying compositions of solvent A (0.1% formic acid, 2 mM ammonium formate in water) and solvent B (acetonitrile) at a flow rate of 0.4 mL/min as follows:
Here is a list of all classes and adducts in the collection:
Name | Subclass | Adduct | m/z | CCS | CCS Calibrant | RT | Gradient |
---|---|---|---|---|---|---|---|
+3O,-2H_C14_Ethyl_BAC | EtBAC | [M]+ | 406.3316 | 208.23 | agilent | 2.95 | 3 |
+3O,-2H_C14_Ethyl_BAC | EtBAC | [M]+ | 406.3316 | 208.23 | agilent | 3.17 | 3 |
+3O,-2H_C16_BAC | BAC | [M]+ | 406.3316 | 205.28 | agilent | 1.56 | 3 |
+3O,-2H_C16_BAC | BAC | [M]+ | 406.3316 | 205.28 | agilent | 2.31 | 3 |
+3O,-2H_C16_BAC | BAC | [M]+ | 406.3316 | 205.28 | agilent | 2.59 | 3 |
+3O,-2H_C16_BAC | BAC | [M]+ | 406.3316 | 205.28 | agilent | 2.9 | 3 |
+3O,-2H_C16_BAC | BAC | [M]+ | 406.3316 | 205.28 | agilent | 3.4 | 3 |
+2O,-2H_C18_BAC | BAC | [M]+ | 418.368 | 209.58 | agilent | 3.02 | 3 |
+2O,-2H_C18_BAC | BAC | [M]+ | 418.368 | 209.58 | agilent | 3.96 | 3 |
+2O,-2H_C18_BAC | BAC | [M]+ | 418.368 | 209.58 | agilent | 4.14 | 3 |